351 research outputs found

    Anode-Coupled Readout for Light Collection in Liquid Argon TPCs

    Get PDF
    This paper will discuss a new method of signal read-out from photon detectors in ultra-large, underground liquid argon time projection chambers. In this design, the signal from the light collection system is coupled via capacitive plates to the TPC wire-planes. This signal is then read out using the same cabling and electronics as the charge information. This greatly benefits light collection: it eliminates the need for an independent readout, substantially reducing cost; It reduces the number of cables in the vapor region of the TPC that can produce impurities; And it cuts down on the number of feed-throughs in the cryostat wall that can cause heat-leaks and potential points of failure. We present experimental results that demonstrate the sensitivity of a LArTPC wire plane to photon detector signals. We also simulate the effect of a 1 μ\mus shaping time and a 2 MHz sampling rate on these signals in the presence of noise, and find that a single photoelectron timing resolution of ∼\sim30 ns can be achieved.Comment: 16 pages, 15 figure

    Control of the woolly apple aphid (Erisoma lanigerum Hausm.) by releasing earwigs (Forficula auricularia L.) and support oil applications - an interim report of first year results

    Get PDF
    The woolly apple aphid (Erisoma lanigerum Hausm.) has been recognised for some years as a serious pest in organic fruit growing where they may cause severe economic damage due to a lack of control strategies. Based on preliminary results a new project has been started in 2007 testing combinations of releasing earwigs and oil applications in order to develop an onfarm control strategy. In this paper we present preliminary results of the first year of the project´s field trials. They showed good efficacies for applying oil preparations by brush. The efficacy of releasing earwigs depended on the infestation intensity

    A Measurement of the Absorption of Liquid Argon Scintillation Light by Dissolved Nitrogen at the Part-Per-Million Level

    Get PDF
    We report on a measurement of the absorption length of scintillation light in liquid argon due to dissolved nitrogen at the part-per-million (ppm) level. We inject controlled quantities of nitrogen into a high purity volume of liquid argon and monitor the light yield from an alpha source. The source is placed at different distances from a cryogenic photomultiplier tube assembly. By comparing the light yield from each position we extract the absorption cross section of nitrogen. We find that nitrogen absorbs argon scintillation light with strength of (1.51±0.15)×10−4  cm−1ppm−1(1.51\pm 0.15)\times10^{-4} \;\mathrm{cm^{-1} ppm^{-1}}, corresponding to an absorption cross section of (7.14±0.74)×10−21  cm2molecule−1(7.14 \pm 0.74)\times10^{-21}\;\mathrm{cm^{2} molecule^{-1}}. We obtain the relationship between absorption length and nitrogen concentration over the 0 to 50 ppm range and discuss the implications for the design and data analysis of future large liquid argon time projection chamber (LArTPC) detectors. Our results indicate that for a current-generation LArTPC, where a concentration of 2 parts per million of nitrogen is expected, the attenuation length due to nitrogen will be 30±330 \pm 3 meters.Comment: v2: Correct mistake in molecular absorption cross section calculation, and a minor typo in fig

    Cyclotrons as Drivers for Precision Neutrino Measurements

    Get PDF
    As we enter the age of precision measurement in neutrino physics, improved flux sources are required. These must have a well-defined flavor content with energies in ranges where backgrounds are low and cross section knowledge is high. Very few sources of neutrinos can meet these requirements. However, pion/muon and isotope decay-at-rest sources qualify. The ideal drivers for decay-at-rest sources are cyclotron accelerators, which are compact and relatively inexpensive. This paper describes a scheme to produce decay-at-rest sources driven by such cyclotrons, developed within the DAEdALUS program. Examples of the value of the high precision beams for pursuing Beyond Standard Model interactions are reviewed. New results on a combined DAEdALUS--Hyper-K search for CP-violation that achieve errors on the mixing matrix parameter of 4 degrees to 12 degrees are presented.Comment: This paper was invited by the journal Advances in High Energy Physics for their upcoming special issue on "Neutrino Masses and Oscillations," which will be published on the 100th anniversary of Pontecorvo's birt

    Improved TPB-coated Light Guides for Liquid Argon TPC Light Detection Systems

    Get PDF
    Scintillation light produced in liquid argon (LAr) must be shifted from 128 nm to visible wavelengths in light detection systems used for liquid argon time-projection chambers (LArTPCs). To date, LArTPC light collection systems have employed tetraphenyl butadiene (TPB) coatings on photomultiplier tubes (PMTs) or plates placed in front of the PMTs. Recently, a new approach using TPB-coated light guides was proposed. In this paper, we report on light guides with improved attenuation lengths above 100 cm when measured in air. This is an important step in the development of meter-scale light guides for future LArTPCs. Improvements come from using a new acrylic-based coating, diamond-polished cast UV transmitting acrylic bars, and a hand-dipping technique to coat the bars. We discuss a model for connecting bar response in air to response in liquid argon and compare this to data taken in liquid argon. The good agreement between the prediction of the model and the measured response in liquid argon demonstrates that characterization in air is sufficient for quality control of bar production. This model can be used in simulations of light guides for future experiments.Comment: 25 pages, 20 figure

    The Effects of Dissolved Methane upon Liquid Argon Scintillation Light

    Get PDF
    In this paper we report on measurements of the effects of dissolved methane upon argon scintillation light. We monitor the light yield from an alpha source held 20 cm from a cryogenic photomultiplier tube (PMT) assembly as methane is injected into a high-purity liquid argon volume. We observe significant suppression of the scintillation light yield by dissolved methane at the 10 part per billion (ppb) level. By examining the late scintillation light time constant, we determine that this loss is caused by an absorption process and also see some evidence of methane-induced scintillation quenching at higher concentrations (50-100 ppb). Using a second PMT assembly we look for visible re-emission features from the dissolved methane which have been reported in gas-phase argon methane mixtures, and we find no evidence of visible re-emission from liquid-phase argon methane mixtures at concentrations between 10 ppb and 0.1%.Comment: 18 pages, 11 figures Updated to match published versio

    The scorpionfly (Panorpa cognata) genome highlights conserved and derived features of the peculiar dipteran X chromosome.

    Get PDF
    Many insects carry an ancient X chromosome - the Drosophila Muller element F - that likely predates their origin. Interestingly, the X has undergone turnover in multiple fly species (Diptera) after being conserved for more than 450 MY. The long evolutionary distance between Diptera and other sequenced insect clades makes it difficult to infer what could have contributed to this sudden increase in rate of turnover. Here, we produce the first genome and transcriptome of a long overlooked sister-order to Diptera: Mecoptera. We compare the scorpionfly Panorpa cognata X-chromosome gene content, expression, and structure, to that of several dipteran species as well as more distantly-related insect orders (Orthoptera and Blattodea). We find high conservation of gene content between the mecopteran X and the dipteran Muller F element, as well as several shared biological features, such as the presence of dosage compensation and a low amount of genetic diversity, consistent with a low recombination rate. However, the two homologous X chromosomes differ strikingly in their size and number of genes they carry. Our results therefore support a common ancestry of the mecopteran and ancestral dipteran X chromosomes, and suggest that Muller element F shrank in size and gene content after the split of Diptera and Mecoptera, which may have contributed to its turnover in dipteran insects
    • …
    corecore